Search

Contacts

Address:Armenia, 0064, Yerevan, 111 Raffi str.
Telephone:+ (374 10) 738323
+ (374 10) 741140
Fax:+ (374 10) 743750
E-mail:info@raomars.com
Manufacture
Back
Test for influence of an environment
The branch is equipped with the modern equipment, enabling an opportunity to test both separate units, and a product as a whole. The following equipment is established: 1. The climatic chamber - low pressure air / dry heat 2. The climatic chamber - humidity / penetration a water / hydrochloric fog / SO2 3. The dust chamber 4. System of test for vibrations 5. System of test for shock loadings 6. System of test for stability radio-frequency handicapes 7. System of test for stability electrostatic categories 8. The climatic chamber - temperature / humidity 9. The chamber of growth of a mould 10. System of the COMPUTER of management of tests for influence of an environment.
The chamber of climatic tests for humidity (a hydrochloric fog)
Manufacture:Dynam Engineering Services Ltd (England)
Description:
The chamber with an adjustable level of humidity and temperatures, means of input Hydrochloric fog and water irrigation. Range of humidity from + 350 up to 600 50 - 95 % Range of temperatures 60 - 1000С It is suitable for a free admission and an output of a case with sizes 1875 х 800м х 625 гл.
Photo:
The dust chamber
Manufacture:Dynam Engineering Services Ltd (England)
Description:
The chamber for modeling conditions of a dust storm. The sizes of particles -50 300 mesh The sizes of particles for tests -100 mesh The admission at regulation t 0C -350 - 2 0C The maximal relative humidity -60% The sizes of a case an input and an output -1875 х 800 х 625
Photo:
System for tests influence of vibrations
Manufacture:Dynam Engineering Services Ltd (England)
Description:
Technological water of -200l/min Load carrying-capacity -400kg
Photo:
System for tests for shock loadings
Manufacture:Lansmont Corporation (England)
Description:
Load carrying-capacity-400kg
Photo:
System of tests for stability radio-frequency handicapes
Manufacture:Electro-Metrics Ltd (England)
Description:
The area of a casing - 5,3м х 6,6м.
Photo:
The chamber for check on stability a mould
Manufacture:Dynam Engineering Services Ltd (England)
Description:
The chamber with regulation of temperature and humidity. The samples placed In the chamber, are loaded by disputes of a mould for supervision over their growth. Range of temperatures and the admission on t0C - 40-1000C ±10C Relative humidity - 10 - 950C Inner sizes (mm) - 610 х 610 х 610
Photo: